Marine / Shipboard Cables
DEF STAN - 02 - 526 (NES 526)
Power Cables, EPR insulated, LFH Elastomeric Sheathed Single Core and Multi Core
Construction | - | Multi Core Cables, Unscreened or Inddividually Screened or Collectively Screened, Limited Fire Hazardous Sheathed. |
Conductor | - | Circular Electroplated & Annealed Tinned Copper |
Insulation | - | Dual Layer of GP5 and LFH Material |
Sreening | - | Annealed Tinned Copper Braid, Individually Screened or Collectively Screened. |
Armouring | GI Wire Braided if applicable. | |
Outer Sheath | - | LFH Elastomeric Compound |
Temperature Range | - | -30° C to + 105° C. |
Application | - | For use on board surface ships, submarines and crafts for power, control, lighting and communication and instrumentation circuits |
DEF STAN - 02 - 527 (NES 527)
Cables for elctric fire survival, high temperature zone and limited fire hazard sheathed.
Construction | - | Single Core, Multi Core, Miniature Multi Core, Multi Pair, Triple, Unscreened or Screened or Individually Screened or Collectively Screened. |
Conductor | - | Circular Electroplated, Annealed Tinned Copper Wire. |
Insulation | - | Silicone Rubber Compund |
Sreening | - | Annealed Tinned Copper Braid, Individually Screened or Collectively Screened. |
Protective Barrier | Glass Braid/Lacquer, Mica Glass ape to meet the fire performance | |
Screening | - | Annealed Tinned Copper Braid with Polyester Separated Tape. |
Outer Sheath | - | LFH Elastomeric Compound |
Temperature Range | - | -30° C to + 105° C. |
Application | - | For use on board surface ships, submarines and crafts for power, control, lighting and communication and instrumentation circuits with fire survival characteristic. |
IEC 60092 - 350, 353, 360 & 376
Cables for elctric fire survival, high temperature zone and limited fire hazard sheathed.
Construction | - | Single Core, Multi Core, Single, Screened & Unscreened , Armoured & Unarmoured |
Conductor | - | Electroplated Annealed Bare/ Tinned Copper of various classes. |
Insulation | - | XLPE/ EPR/ HEPR/ HF 90/ S 95 |
Sreening | - | Almylar Screen along with Drain Wire |
Inner Sheath | SHF1/ SHF2/ SH/ SF | |
Armouring | - | Bare Copper/ Tinned Copper/ GI Wire Braid Armoured with >90% coverage |
Outer Sheath | - | SHF1/ SHF2/ SH/ SF |
Temperature Range | - | -30° C to + 105° C. |
Application | - | For use on board surface ships for power control, lighting and communication and instrumentation circuits |