These cables are used in conveyor machinery such as transfer cars, boom-stackers, side arm chargers, bulk material conveyors etc.

They find application in almost every industry segment like Steel Mills, Cement Plants, Docks, Power Plants, Automobile Industries & Refineries and Petrochemicals.

Construction
Single cable comprising multiple elements like power cores, control
cores, signaling pairs, etc for multipurpose functions.
Voltage Grade600 / 1100 V AC
Conductor
Class-5 flexible tinned or bare copper
InsulationEPR
ScreeningTinned or bare copper wire braid
Inner SheathHOFR- Elastomer
Anti Kink BraidFabric braid embedded between inner and outer sheath
Outer SheathHOFR Elastomer
FeaturesDesigned to withstand continuous reeling and unreeling
Sheath materials that have a high degree of flex fatigue resistance
Excellent heat, oil and fire resistant properties
Operating Temperature-20° C to +90° C
Test Voltage2500 V AC
Bending Radius10 D
Core Marking1-5 cores colour coded as Green / Yellow, Blue, Brown, Black, Grey or
Coloured Rubberised cotton tapes. 6 cores and above with numbered
cores, with one earth core of Green / Yellow.
StandardsIEC-60228, IEC-60502, IEC-60332