Cable Type | Specification | Voltage Grade |
Railway rolling stock high temperature power cables having special fire performance | BSEN 50382-1 &
BSEN 50382-2 |
· 1.8 / 3 KV unscreened, unsheathed with or without textile braid (1.5 mm² to 400 mm²)
· 1.8 / 3 KV unscreened, sheathed (1.5 mm² to 400 mm²) · 3.6 / 6 KV unscreened, unsheathed with or without textile braid (2.5 mm² to 400 mm² · 3.6 / 6 KV unscreened, sheathed (2.5 mm² to 400 mm²) . Operating Temperature: -50 to 150° C / -40 to 120° C |
Railway rolling stock power and control cables having special fire performance | BSEN-50264-1, BSEN-50264-3-1, BSEN-50264-3-2 | · 0.6 / 1 KV unscreened & Unsheathed(1 sq.mm to 400 sq.mm)
· 1.8 / 3 KV unscreened & Unsheathed(1.5 sq.mm to 400 sq.mm) · 1.8 / 3 KV unscreened & Sheathed(1.5 sq.mm to 400 sq.mm) · 3.6 / 6 KV unscreened & Sheathed(2.5 sq.mm to 400 sq.mm) . Operating Temperature: -40 to 120° C
|
Railway rolling stock cables having special fire performance thin wall | BSEN-50306-1, BSEN-50306-2, BSEN-50306-3 & BSEN-50306-4 | · EN 50306-4 specifies requirements for, and constructions and dimensions of multi core & multi pairs cables, rated 300 V to earth, of the following type:
· Unscreened, sheathed for either exposed or protected wiring (size:0.5 to 2.5 sq.mm & no of cores:2 to 48) · Screened, sheathed for either exposed or protected wiring (size:0.5 to 2.5 sq.mm & no of cores:2 to 8) · Screened, sheathed for either exposed or protected wiring (size:0.5 to 2.5 sq.mm & no of cores:2 to 7) . Operating Temperature: -40 to 105° C |