Offering exceptional flame resistance, durability and EMC compatibility, these cables are ideal for fixed installations in locomotives, metros & EMUs.
| Application | Used for power transmission, controlling in various application in Railway Rolling Stock (Locomotives, Metros, EMU, MEMU)
They are suitable for use in confined spaces due to their reduced bending radius. They can withstand harsh operating conditions, including exposure to oil, ozone and wide temperature fluctuations. The conductors are rated for continuous operation at temperatures 90° C (Optional: 120° C) |
| Advantages | Halogen-free, fire safety by reducing flame spread, smoke and toxic gas emissions.
They are resistant to oils, fuels and ozone, ensuring durability and reliable performance even when exposed to harsh chemicals. They can withstand mechanical stresses like vibration and impact, which are common in railway environments. |
Single Core Cables
| Component | 0.6/1 KV (Unsheathed) M |
1.8/3 KV (Unsheathed) M |
1.8/3 KV (Sheathed) MM |
3.6/6 KV (Sheathed) MM |
| Size (sq.mm) | 1.0 sq.mm to 400 sq.mm | 1.5 sq.mm to 400 sq.mm | 1.5 sq.mm to 400 sq.mm | 2.5 sq.mm to 400 sq.mm |
| Operating temperature | – 40° C to +90° C / +120° C | |||
| Flexible Tinned Coated Annealed Copper Conductor (Class 5) |
![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() |
![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() |
![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() |
![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() |
| Conductor screening | ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() |
![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() |
![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() |
![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() |
| Separator Tape | (Optional) | (Optional) | (Optional) | ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() |
| Insulation (Type EI 106/107/108/109/110) | ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() |
![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() |
![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() |
![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() |
| Separator Tape | ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() |
![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() |
(Optional) | (Optional) |
| Sheath (Type EM 101/102/103/104) | ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() |
![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() |
![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() |
![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() |
| Test Voltage | 3.5 KV for 5 min | 6.5 KV for 5 min | 6.5 KV for 5 min | 11 KV for 5 min |



Not sure where to start? Try our products
Our solution can find thermosystems products
REQUEST A CALL BACK