Electron beam irradiated thin walled flexible elastomeric cables with copper conductor, limited fire hazard, minimum flame spread, low smoke emission & limited toxic fumes emission.
| Application | They are designed for fixed, protected internal use in power, auxiliary as well as control circuit of conventional tap changer electric locomotives, AC/DC EMU & BG AC EMU & MEMU / Coaching Stock.
They offer robust resistance to oil, fuel, ozone and temperature extremes. Critically, their construction ensures superior fire performance meeting ELRS / ELC / SPEC / 0019 requirements along with EN 45545-2 HL3 |
| Advantages | It’s construction provides extreme durability against mechanical stress, chemicals and temperature fluctuations
Halogen-free, fire safety by reducing flame spread, smoke and toxic gas emissions Resistance to mineral oil, diesel oil, fluids & ozone Thin-wall design allows for space-efficient installation Robust build guarantees a long service life |
| Construction: | Single Core Cables | Multi Core Cables | ||
| Component | up to 750 V | Above 750 & Up To 1.8/3 KV | Above 750 & Up To 1.8/3 KV | |
| Size (sq.mm) | 1.5 sq. mm to 150 sq. mm |
1.5 sq. mm to 300 sq. mm |
19C X 2.5 sq. mm | 19C X 4 sq. mm |
| Operating temperature | – 40° C to +120° C | |||
| Electrolytic Flexible Annealed Tinned Copper (Class-5) |
![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() |
![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() |
![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() |
![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() |
| Insulation (Type EBXL EPDM ) | ![]() ![]() ![]() ![]() ![]() |
![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() |
![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() |
![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() |
| Insulation (Type EBXL EVA ) | ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() |
![]() ![]() ![]() ![]() ![]() |
![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() |
![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() |
| Sheath-Type EBXL EVA | ![]() ![]() ![]() ![]() ![]() |
![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() |
![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() |
![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() |
| HV Test | 6 KV for 5min | 8 KV for 15min | ||
| HV Test-At room temp. at 90 ± 3° C |
K ≥ 2000 MΩ-km K ≥ 30 MΩ-km |
K ≥ 12000 MΩ-km K ≥ 200 MΩ-km |
||
| Bending Radius: | 3 X OD for cable diameter < 10mm 5 X OD for cable diameter > 10mm | |||
Colors: Various color options available as per customer requirement (Red, Yellow, Blue, Black, Grey, GNYE, Chocolate, White, etc.).
![]()
![]()
![]()